{"msg":"OK","data":{"summary":"一、项目基本情况原公告的采购项目编号:JSZC-320100-JSGC-G2024-0084 原公告的采购项目名称:南京城墙及内部空间消防隐患整改项目 首次公告日期:2024-10-29 二、更正信息更正事项:采购文件 更正内容:更正内容(一):原招标文件第四章-产品清单及技术参数内容:序号设备名称参数要求71▲高压细","projId":"f1f8a6bb712f4c8494d4bfdfbca57b1d","pLmId":"","ggCode":"gzgg","publishDate":"2024-11-11 10:51:59","title":"南京城墙及内部空间消防隐患整改项目更正公告(二)","type":1,"content":"

<\/h1>\n

一、项目基本情况<\/span><\/h2>\n

原公告的采购项目编号:JSZC-320100-JSGC-G2024-0084<\/span> <\/span><\/p>\n

原公告的采购项目名称:南京城墙及内部空间消防隐患整改项目<\/span> <\/span><\/p>\n

首次公告日期:2024-10-29<\/span> <\/span><\/p>\n

二、更正信息<\/span><\/h2>\n

更正事项:采购文件<\/span> <\/span><\/p>\n

更正内容:<\/span><\/p>\n

\n

更正内容(一):<\/span><\/p>\n

原招标文件第四章<\/span>-产品清单及技术参数内容:<\/span><\/p>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
\n

序号<\/span><\/strong><\/p>\n<\/td>\n

\n

设备名称<\/span><\/strong><\/p>\n<\/td>\n

\n

参数要求<\/span><\/strong><\/p>\n<\/td>\n<\/tr>\n

\n

71<\/span><\/p>\n<\/td>\n

\n

▲高压细水雾泵组<\/span><\/p>\n<\/td>\n

\n

高压细水雾泵组<\/span>,含泵、泵控柜、水箱、机架等。南京城墙是国家重点保护文物,泵房至保护区较远,对于城墙文物建筑不能破坏,管道路径需要绕行加长,水头损失较大,对泵组压力及流量有以下要求,高压泵组的工作压力P=16MPa,泵组流量Q≥400L/min。<\/span>(参数正负偏离不得超过<\/span>5%,提供型式检验报告扫描件、厂家授权书扫描件并加盖制造商或投标人公章证明)<\/span><\/strong><\/p>\n<\/td>\n<\/tr>\n

\n

72<\/span><\/p>\n<\/td>\n

\n

高压单泵:<\/span>Q=100L/min,H=16MPa,N=30kW<\/span><\/p>\n<\/td>\n

\n

高压单泵:<\/span>Q=100L/min,H=16MPa,N=30kW,四用一备,N=120KW<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

74<\/span><\/p>\n<\/td>\n

\n

高压细水雾湿式区域阀组<\/span><\/p>\n<\/td>\n

\n

高压细水雾湿式区域阀组,单阀箱,<\/span>XSW-FZ32/16-B TH<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

75<\/span><\/p>\n<\/td>\n

\n

▲高压细水雾闭式喷头<\/span><\/p>\n<\/td>\n

\n

高压细水雾闭式喷头,细水雾保护区有电气设备及重要文物建筑,对细水雾雾滴直径有以下要求,喷头最低工作压力不小于<\/span>10MPa,雾滴直径优于Dv0.99≤80μm,Dv0.50≤45μm。<\/span>(提供雾滴直型式检验报告扫描件、厂家授权书扫描件并加盖制造商或投标人公章证明)<\/span><\/strong><\/p>\n<\/td>\n<\/tr>\n

\n

77<\/span><\/p>\n<\/td>\n

\n

高压细水雾喷枪装置<\/span><\/p>\n<\/td>\n

\n

高压细水雾喷枪装置,<\/span>QGX-40/10 TH,含喷枪箱、喷枪、卷盘、球阀、软管等<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

158<\/span><\/p>\n<\/td>\n

\n

移动式高压细水雾灭火装置<\/span>,QXWL14/35BC-T125-RS01<\/span><\/p>\n<\/td>\n

\n

移动式高压细水雾灭火装置<\/span>,QXWL14/35BC-T125-RS01<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

261<\/span><\/p>\n<\/td>\n

\n

▲高压细水雾泵组<\/span><\/p>\n<\/td>\n

\n

高压细水雾泵组<\/span>,含泵、泵控柜、水箱、机架等。南京城墙是国家重点保护文物,泵房至保护区较远,对于城墙文物建筑不能破坏,管道路径需要绕行加长,水头损失较大,对泵组压力及流量有以下要求,高压泵组的工作压力P=16MPa,泵组流量Q≥400L/min。<\/span>(参数正负偏离不得超过<\/span>5%,提供型式检验报告扫描件、厂家授权书扫描件并加盖制造商或投标人公章证明)<\/span><\/strong>。<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

262<\/span><\/p>\n<\/td>\n

\n

高压单泵:<\/span>Q=100L/min,H=16MPa,N=30kW<\/span><\/p>\n<\/td>\n

\n

高压单泵:<\/span>Q=100L/min,H=16MPa,N=30kW,四用一备,N=120KW<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

264<\/span><\/p>\n<\/td>\n

\n

高压细水雾开式区域阀组<\/span><\/p>\n<\/td>\n

\n

高压细水雾开式区域阀组,单阀箱,<\/span>XSW-FZ15/16 TH<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

265<\/span><\/p>\n<\/td>\n

\n

高压细水雾湿式区域阀组<\/span><\/p>\n<\/td>\n

\n

高压细水雾湿式区域阀组,单阀箱,<\/span>XSW-FZ20/16-B TH<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

266<\/span><\/p>\n<\/td>\n

\n

高压细水雾湿式区域阀组<\/span><\/p>\n<\/td>\n

\n

高压细水雾湿式区域阀组,单阀箱,<\/span>XSW-FZ32/16-B TH<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

267<\/span><\/p>\n<\/td>\n

\n

▲高压细水雾闭式喷头<\/span><\/p>\n<\/td>\n

\n

高压细水雾闭式喷头,细水雾保护区有电气设备及重要文物建筑,对细水雾雾滴直径有以下要求,喷头最低工作压力不小于<\/span>10MPa,雾滴直径优于Dv0.99≤80μm,Dv0.50≤45μm。<\/span>(提供雾滴直型式检验报告扫描件、厂家授权书扫描件并加盖制造商或投标人公章证明)<\/span><\/strong><\/p>\n<\/td>\n<\/tr>\n

\n

269<\/span><\/p>\n<\/td>\n

\n

高压细水雾喷枪装置<\/span><\/p>\n<\/td>\n

\n

高压细水雾喷枪装置,<\/span>QGX-40/10 TH,含喷枪箱、喷枪、卷盘、球阀、软管等<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

现更正为:<\/span><\/strong><\/p>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
\n

序号<\/span><\/strong><\/p>\n<\/td>\n

\n

设备名称<\/span><\/strong><\/p>\n<\/td>\n

\n

参数要求<\/span><\/strong><\/p>\n<\/td>\n<\/tr>\n

\n

71<\/span><\/p>\n<\/td>\n

\n

▲高压细水雾泵组<\/span><\/p>\n<\/td>\n

\n

高压细水雾泵组<\/span>,含泵、泵控柜、水箱、机架等。南京城墙是国家重点保护文物,泵房至保护区较远,对于城墙文物建筑不能破坏,管道路径需要绕行加长,水头损失较大,对泵组压力及流量有以下要求,高压泵组的工作压力P=16MPa,泵组流量Q≥400L/min。<\/span>(提供型式检验报告扫描件、厂家授权书扫描件并加盖制造商或投标人公章证明)<\/span><\/strong><\/p>\n<\/td>\n<\/tr>\n

\n

72<\/span><\/p>\n<\/td>\n

\n

高压单泵:<\/span>Q=100L/min,H=16MPa,N=30kW<\/span><\/p>\n<\/td>\n

\n

高压单泵:<\/span>Q≥100L/min,H=16MPa,N=30kW,四用一备,N=120KW<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

74<\/span><\/p>\n<\/td>\n

\n

高压细水雾湿式区域阀组<\/span><\/p>\n<\/td>\n

\n

高压细水雾湿式区域阀组,单阀箱,<\/span>XSW-FZ32/16<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

75<\/span><\/p>\n<\/td>\n

\n

▲高压细水雾闭式喷头<\/span><\/p>\n<\/td>\n

\n

高压细水雾闭式喷头,细水雾保护区有电气设备及重要文物建筑,对细水雾雾滴直径有以下要求,喷头最低工作压力不小于<\/span>10MPa,雾滴直径优于Dv0.99≤80μm,Dv0.50≤45μm。<\/span>(投标人承诺如中标后在项目验收之前提供雾滴直型式检验报告扫描件加盖投标人公章交至采购人核查)<\/span><\/strong><\/p>\n<\/td>\n<\/tr>\n

\n

77<\/span><\/p>\n<\/td>\n

\n

高压细水雾喷枪装置<\/span><\/p>\n<\/td>\n

\n

高压细水雾喷枪装置,<\/span>QGX-40/10,含喷枪箱、喷枪、卷盘、球阀、软管等<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

158<\/span><\/p>\n<\/td>\n

\n

移动式高压细水雾灭火装置<\/span><\/p>\n<\/td>\n

\n

移动式高压细水雾灭火装置<\/span>,<\/span> QXWL12.5/20BC- T125<\/p>\n<\/td>\n<\/tr>\n

\n

261<\/span><\/p>\n<\/td>\n

\n

▲高压细水雾泵组<\/span><\/p>\n<\/td>\n

\n

高压细水雾泵组<\/span>,含泵、泵控柜、水箱、机架等。南京城墙是国家重点保护文物,泵房至保护区较远,对于城墙文物建筑不能破坏,管道路径需要绕行加长,水头损失较大,对泵组压力及流量有以下要求,高压泵组的工作压力P=16MPa,泵组流量Q≥400L/min。<\/span>(提供型式检验报告扫描件、厂家授权书扫描件并加盖制造商或投标人公章证明)<\/span><\/strong>。<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

262<\/span><\/p>\n<\/td>\n

\n

高压单泵:<\/span>Q=100L/min,H=16MPa,N=30kW<\/span><\/p>\n<\/td>\n

\n

高压单泵:<\/span>Q≥100L/min,H=16MPa,N=30kW,四用一备,N=120KW<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

264<\/span><\/p>\n<\/td>\n

\n

高压细水雾开式区域阀组<\/span><\/p>\n<\/td>\n

\n

高压细水雾开式区域阀组,单阀箱,<\/span>XSW-FZ15/16 <\/span><\/p>\n<\/td>\n<\/tr>\n

\n

265<\/span><\/p>\n<\/td>\n

\n

高压细水雾湿式区域阀组<\/span><\/p>\n<\/td>\n

\n

高压细水雾湿式区域阀组,单阀箱,<\/span>XSW-FZ20/16<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

266<\/span><\/p>\n<\/td>\n

\n

高压细水雾湿式区域阀组<\/span><\/p>\n<\/td>\n

\n

高压细水雾湿式区域阀组,单阀箱,<\/span>XSW-FZ32/16<\/span><\/p>\n<\/td>\n<\/tr>\n

\n

267<\/span><\/p>\n<\/td>\n

\n

▲高压细水雾闭式喷头<\/span><\/p>\n<\/td>\n

\n

高压细水雾闭式喷头,细水雾保护区有电气设备及重要文物建筑,对细水雾雾滴直径有以下要求,喷头最低工作压力不小于<\/span>10MPa,雾滴直径优于Dv0.99≤80μm,Dv0.50≤45μm。<\/span>(投标人承诺如中标后在项目验收之前提供雾滴直型式检验报告扫描件加盖投标人公章交至采购人核查)<\/span><\/strong><\/p>\n<\/td>\n<\/tr>\n

\n

269<\/span><\/p>\n<\/td>\n

\n

高压细水雾喷枪装置<\/span><\/p>\n<\/td>\n

\n

高压细水雾喷枪装置,<\/span>QGX-40/10 ,含喷枪箱、喷枪、卷盘、球阀、软管等。<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

更正内容(二):<\/span><\/p>\n

原招标文件第一章内容:<\/span><\/p>\n

项目概况<\/span><\/p>\n

南京城墙及内部空间消防隐患整改项目<\/span> JSZC-320100-JSGC-G2024-0084招标项目的潜在投标人应在江苏政府采购网\u201c苏采云\u201d系统获取招标文件,并于 2024年11月19日9:30(北京时间)前提交投标文件。<\/p>\n

四、提交投标文件截止时间、开标时间和地点<\/span><\/p>\n

2024年11月19日 9:30 (北京时间)<\/p>\n

地点:<\/span>\u201c苏采云\u201d系统开标大厅<\/span><\/p>\n

现更正为:<\/span><\/strong><\/p>\n

项目概况<\/span><\/p>\n

南京城墙及内部空间消防隐患整改项目<\/span> JSZC-320100-JSGC-G2024-0084招标项目的潜在投标人应在江苏政府采购网\u201c苏采云\u201d系统获取招标文件,并于 2024年11月27<\/span>日<\/span>9:30(北京时间)前提交投标文件。<\/p>\n

四、提交投标文件截止时间、开标时间和地点<\/span><\/p>\n

2024年11月27<\/span>日<\/span> 9:30 (北京时间)<\/p>\n

地点:<\/span>\u201c苏采云\u201d系统开标大厅<\/span><\/p>\n<\/div>\n

更正日期:2024-11-11<\/span> <\/span><\/p>\n

三、其他补充事宜<\/span><\/h2>\n
\n

其他内容不变。<\/span><\/p>\n<\/div>\n

四、凡对本次公告内容提出询问,请按以下方式联系<\/span><\/h2>\n

1.采购人信息<\/span><\/p>\n

\n

单位名称:南京城墙保护管理中心<\/p>\n

单位地址:南京市秦淮区边营1号<\/p>\n

联系人:杨帆<\/p>\n

联系电话:18013857315<\/p>\n<\/div>\n

2.采购代理机构信息(如有)<\/span><\/p>\n

\n

单位名称:江苏国采工程咨询有限公司<\/p>\n

单位地址:南京市山西路8号金山大厦A座28层2810室<\/p>\n

联系人:张近 陈丹<\/p>\n

联系电话:025-83690878<\/p>\n<\/div>\n

3.项目联系方式<\/span><\/p>\n

\n

项目联系人:张近 陈丹<\/p>\n

电话:025-83690878<\/p>\n<\/div>\n

五、附件<\/span>(<\/span>适用于更正中标、成交供应商<\/span><\/em>)<\/span><\/span><\/h2>\n
\n

无<\/p>\n<\/div>","lmId":"","pZoneName":"江苏省","pLmName":"","files":[{"name":"JSZC-320100-JSGC-G2024-0084采购文件.doc","url":"http://www.ccgp-jiangsu.gov.cn/fileApi/320000/fad719896db44ff99ddb2c103b090907.doc"}],"siteId":"1","id":"597bc4f43adc486da996906857e58a48","zoneName":"南京市","pZoneCode":"320000","lmName":"","zoneCode":"320100"}}